Solar Inverter SolarMax 5000P, 5000 Watts, 2xMMP, Output 230VAC, 50Hz
Solar Inverter SolarMax 5000P, 5000 Watts, 2xMMP, Output 230VAC, 50Hz is backordered and will ship as soon as it is back in stock.
SolarMax 5000P Specifications:
Input values
- MPP voltage range: 260 .. 480 V (For AC Rated Power Output)
- Total MPP operating voltage range: 120 ... 580 V
- Minimum DC voltage: 120 V
- Maximum DC voltage: 600 V
- Maximum DC current: 10 + 10 A
- Number of MPP trackers: 2
- Number of string connections: 2
- Connection type: Wieland PST40i1 (MC4 identical in design)
Output values
- Rated output power: 5’000 W (Depending on country setting)
- Maximum apparent output power: 5’000 VA (Depending on country setting)
- Maximum AC current: 22 A
- Nominal mains voltage / range: 230 V / 184 .. 276 V
- Mains nominal frequency / range: 50 Hz / 45 Hz…55 Hz
- Power factor cos(φ): Adjustable from 0.8 overexcited to 0.8 underexcited
- Distortion factor at rated output power: < 3 %
- Connection type: Terminal (2.5 – 10 mm2)
- Grid connection: Single phase (L / N / PE)
- Power input at night: 0W
Efficiency
- Maximum efficiency: 98.0 %
- Europ. Efficiency: 97.5 %
Ambient conditions
- Protection type: IP65
- Ambient temperature range (for rated power output): -20 °C…+60 °C (+45°C)
- Relative humidity: 0…100% (condensation)
- Max. operating level above sea level: 2000m (without derating)
- Fire protection class: V0
- Noise emissions: < 30 dB(A) (↔ 1.5 m)
Configuration
- Display: Graphic LC display with backlighting and status LED
- Inverter topology: HERIC®, transformerless
- DC disconnector: Integrated
- Data logger: Energy yield, peak output and operating hours of the last 31 days, 12 months, 10 years. Performance curves of the last 7 days.
- Fault current monitoring: Internal, AC/DC sensitive
- Housing / service cover: Aluminium / plastic ASA+PC
- Surge protection DC and AC: Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11)
Standards & guidelines
- CE-compliant: Yes
- EMC: EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3
- Grid connection: VDE 0126-1-1 A1:2012 / RD 661 / RD 1699 / G83/2 / G59/2 / PPC Guide / C10/11 / EN 50438 / AS4777
- Device safety: IEC/ EN 62109-1/ -2
Interfaces
- Data communication: RS485 / Ethernet (Plug&Play)
- Status signalling contact: With optional I/O module
- Connection ripple control signal receiver: With optional I/O module
- Connection of external lightning protection control: With optional I/O module
- Connection external grid monitoring: With optional I/O module
- Connection of external energy meter: With optional I/O module
Weight & dimensions
- Weight: 19 kg
- Dimensions in mm (W x H x D): 476 x 360 x 180mm
Note: Inverter had been manufactured by the Swiss Company: Sputnik Engineering